Skip to main content

NiMH BATTERY

The NiMH battery is considered to be a successor to the long-time market dominator the Nickel Cadmium (Ni-Cd) battery system. These cells have been in existence since the turn of the century. The Ni-Cd battery system started with a modest beginning, but with significant advances in the last four decades since the 1950s, the specific capacity of the batteries has improved fourfold. A strong growth of the rechargeable battery consumer appliance market for laptop computers, mobile phones, and camcorders pushed the battery performance requirements particularly service output duration even further. This factor, along with environmental concerns, has accelerated the development of the alternate NiMH system. Since its inception in the early to mid 1980s, the market share of the rechargeable NiMH battery has grown to 35% and the capacity, particularly the high-load capability, has been improving dramatically.

The scientific publications and patent literature provide an extensive number of reports regarding the different aspects of NiMH batteries, including chemistry and hydrogen storage properties of cathode materials.

However, it is important to understand design criteria that optimize performance and extend the cycle life of NiMH batteries.

AB5 (LaNi5) and AB2 (TiN2) alloy compounds have been studied as part of NiMH battery design. Both these alloys have almost similar hydrogen storage capacities, approximately 1.5% by weight. The theoretical maximum hydrogen storage capacities of AB2 alloys is slightly higher, 2% by weight than the maximum of 1.6% by weight for AB5 alloys. The higher AB2 hydrogen storage capacity by weight can be exploited only if the battery size is made larger. This becomes an undesirable factor for compact EV battery designs. The basic concept of the NiMH battery cathode results from research of metallic alloys that can capture (and release) hydrogen in volumes up to a thousand times of their own. The cathode mainly consists of a compressed mass of fine metal particles.

The much smaller hydrogen atom, easily absorbed into the interstices of a bimetallic cathode is known to expand up to 24 volume percent.

The hydride electrode has capacity density of up to 1,800mAh/cm3. Thus for the smaller size NiMH battery, the higher energy density for AB5 alloys, about 8–8.5g/cm3 compared to relatively lower energy density for AB2 alloys, about 5–7g/cm3 results in a battery with comparable energy density.

The conventional, although not cost-effective processing method for manufacturing the AB5 battery materials includes:

Step 1: Melting and rapidly cooling of large metals ingots

Step 2: Extensive heat treatment to eliminate microscopic compositional inhomogeneities

Step 3: Breaking down the large metal ingots into smaller pieces by the hydriding and dehydriding process

Step 4: Grinding of the annealed ingots pieces into fine powders

This four-step manufacturing process is the key-limiting factor to widespread commercialization of NiMH batteries. This process can be eliminated and replaced by a single step using rapid solidification processing of AB5 powders using high-pressure gas atomization. The H2 gas absorption and desorption behavior of the high-pressure gas atomization processed alloy is also significantly improved with the annealing of the powder.

Comments

Popular posts from this blog

PRIMARY SECONDARY AND TERTIARY FREQUENCY CONTROL IN POWER SYSTEMS

Primary, Secondary and Tertiary Frequency Control in Power Systems Author: Engr. Aneel Kumar Keywords: frequency control, primary frequency control, automatic generation control (AGC), tertiary control, load-frequency control, grid stability. Frequency control keeps the power grid stable by balancing generation and load. When generation and demand drift apart, system frequency moves away from its nominal value (50 or 60 Hz). Grids rely on three hierarchical control layers — Primary , Secondary (AGC), and Tertiary — to arrest frequency deviation, restore the set-point and optimize generation dispatch. Related: Power System Stability — causes & mitigation Overview of primary, secondary and tertiary frequency control in power systems. ⚡ Primary Frequency Control (Droop Control) Primary control is a fast, local response implemented by generator governors (dro...

Advantages of Per Unit System in Power System Analysis | Electrical Engineering

  Advantages of Per Unit System in Power System Analysis In electrical power engineering, the per unit (p.u.) system is one of the most widely used techniques for analyzing and modeling power systems. It is a method of expressing electrical quantities — such as voltage, current, power, and impedance — as fractions of chosen base values rather than their actual numerical magnitudes. This normalization technique provides a universal language for system calculations, minimizing errors, simplifying transformer modeling, and enabling consistency across multiple voltage levels. Because of these benefits, the per unit system is essential in fault analysis, load flow studies, transformer testing, and short-circuit calculations . ⚡ What is the Per Unit System? The per unit system is defined as: Q u a n t i t y ( p u ) = A c t u a l   V a l u e B a s e   V a l u e Quantity_{(pu)} = \dfrac{Actual \ Value}{Base \ Value} Q u an t i t y ( p u ) ​ = B a se   ...

CASCADED TRANSFORMERS METHOD FOR GENERATING AC HIGH VOLTAGE

High-Frequency AC High Voltage Generation Using Cascaded Transformers Author: Engr. Aneel Kumar Figure 1: Infographic representation of cascaded transformers method for generating high AC voltages. Introduction In high voltage engineering , generating very high alternating current (AC) voltages is essential for testing equipment like insulators, circuit breakers, power cables, and other apparatus. One common and effective method for producing such voltages is the cascaded transformers method . This technique uses a series connection of specially designed test transformers , where the secondary of one transformer feeds the primary of the next. In this way, voltages are built up step by step, achieving levels in the range of hundreds of kilovolts (kV) or even megavolts (MV). Working Principle The principle of cascaded connection relies on the fact that each...

ADVANTAGES AND DISADVANTAGES OF CORONA EFFECT IN TRANSMISSION LINES | ELECTRICAL ENGINEERING GUIDE

Advantages and Disadvantages of Corona Effect in Power Systems In high-voltage overhead transmission lines , the corona effect plays a critical role in system performance. Corona occurs when the air around a conductor becomes ionized due to high electric stress. While often seen as a drawback because of power losses and interference , it also provides certain engineering benefits . This article explains the advantages and disadvantages of corona effect in detail, with examples relevant to modern electrical power systems. ✅ Advantages of Corona Effect Increase in Virtual Conductor Diameter Due to corona formation, the surrounding air becomes partially conductive, increasing the virtual diameter of the conductor. This reduces electrostatic stress between conductors and minimizes insulation breakdown risks. Related Reading: Electrostatic Fields in High Voltage Engineering Reduction of Transient Surges Corona acts like a natural cushion for sudden ...

Control Strategies for TCSC: Techniques for Dynamic Power Flow Management

Introduction As power transmission networks grow more complex, real-time voltage and impedance control becomes essential for ensuring grid reliability. Thyristor Controlled Series Capacitors (TCSC) play a key role in dynamically adjusting transmission line reactance, but their effectiveness depends on advanced control strategies . Different control methodologies —ranging from open-loop and closed-loop systems to AI-driven predictive models —allow TCSC to optimize power flow, improve stability, and enhance energy efficiency . In this article, we will explore: ✅ Different types of TCSC control strategies ✅ The role of real-time monitoring in optimizing power flow ✅ How AI and machine learning improve TCSC performance Keywords:   AI-Based Power Flow Control,  TCSC Dynamic Impedance Regulation,  Real-Time Voltage Stabilization,  Smart Grid FACTS Controllers Understanding TCSC Control Strategies A TCSC regulates transmission line reactance by adjusting thyristor switch...

ADVANTAGES OF INTERCONNECTED GRID SYSTEM

Interconnected Grid System: Working, Advantages, Disadvantages, and Comparison with Isolated Grids Author: Engr. Aneel Kumar Figure 1: Infographic showing key advantages of an interconnected grid system. Introduction An interconnected grid system refers to a network of multiple power generation sources, transmission lines, substations, and distribution systems that are linked across regions, states, or even countries. Unlike an isolated grid (or islanded grid) which operates independently, an interconnected grid allows electricity to flow between interconnected nodes, enabling numerous benefits and some trade-offs. In today’s energy landscape—where demand, renewable generation, reliability, and cost pressure are all increasing—understanding how an interconnected grid works, what factors are essential, and what its advantages and disadvantages are is critical for utility planners, reg...

DIFFERENCE BETWEEN GRID STATION AND SUB STATION

An electrical power substation is a conversion point between transmission level voltages (such as 138 KV) and distribution level voltages (such as 11 KV). A substation has one or more step-down transformers and serves a regional area such as part of a city or neighborhood. Substations are connected to each other by the transmission ring circuit. An electrical grid station is an interconnection point between two transmission ring circuits, often between two geographic regions. They might have a transformer, depending on the possibly different voltages, so that the voltage levels can be adjusted as needed. The interconnected network of grid stations is called the grid, and may ultimately represent an entire multi-state region. In this configuration, loss of a small section, such as loss of a power station, does not impact the grid as a whole, nor does it impact the more localized neighborhoods, as the grid simply shifts its power flow to compensate, giving the power station o...