OPTIMUM LOADING OF HYBRID SUPPLY SYSTEM FOR RESIDENTIAL CUSTOMER

1. Introduction

The hybrid power system is a comprehensive electrical power supply system that can be easily configured to meet a broad range of power needs. Hybrid systems, like the name implies, combine two or more modes of electricity generation together, usually using renewable technologies such as solar photovoltaic (PV) and wind turbines. Hybrid systems provide a high level of energy security through the mix of generation methods, and often will incorporate a storage system (battery, fuel cell) or gird tied supply system to ensure maximum supply reliability and security.

There are three basic elements to this system - the power source, the battery, and the power management center. Power sources are wind turbine, solar energy and grid connection. The battery allows autonomous operation by compensating for the difference between power production and utilization. The power management center regulates power production from each of the sources, controls power use by classifying loads, and protects the battery from service extremes. Figure 1 shows a simple arrangement for a hybrid system comprising of solar and wind generations, connection to the existing utility network. Power can be taken from utility or can be feed back to utility.



Figure 1 Hybrid supply system concept 

In general, Hybrid Power Systems have to meet different requirements depending on the appliances served, the consumer behavior, the consumer’s demands on the power quality and the energy sources available locally. While mobile phone antennas need to be supplied with almost constant power of high quality, small villages have a fluctuating and usually growing energy demand while short term power outages are not critical.

To realize cost efficient power supply with the required power quality an individual system design considering all site specific aspects is essential.

2. Solar Energy

The Solar Modules (Photovoltaic Cell) generate DC electricity when ever sun light falls in solar cells. The Solar Modules should be titled in an optimum angle for the particular location face due to south, and should not be shaded at any time in a day. Motorized control can be used to rotate solar panels in the direction of sun and ensure maximum sun light.



Figure 2 Solar system components

3. Wind Energy

Wind is the natural phenomenon related to the movement of air masses caused by the primarily by the differential solar heating of the earth’s surface. Seasonal variation in the energy received from the sun affects the strength and direction of the wind. The wind turbine capture the wind kinetic energy in a rotor consisting of two or more blades mechanically coupled to an electrical generator. The turbine is mounted on a tall tower to enhance the energy capture.



Figure 3 Wind system components

4. Grid Power

Electrical power is generated in bulk amount and transmitted to power grid and then distributed to the consumers. Its performance affects the consumers ‘appliances and also the economy of the power system. Existing system near the consumers is a three phase four wire system.

5. Literature Review

Parita G Dilwadi and Chintan R Mehta (March 2012) Calculated the cost of production of energy and it is also conclude that initial cost of the Wind solar hybrid system is high but it produces energy at least cost.

(1) M. Partovi and M.Mohammadian (March 2013) Study about Economic model of the FC-PV hybrid supply system and also estimate the daily optimal strategy for the hybrid system and to minimize the operation cost.

(2) F.D Surianu I. Borlea D.Jagoria Oprea and B Lustrea (March 2012) studies shows the broad utilization of the renewable energy resources, and also shows the comparison of renewable energy resources (3)

6. Objectives of the research

The objectives of the research project are to perform the operational studies for hybrid supply system and planning studies to optimum loading in the hybrid supply system, enhance reliability and Uninterrupted power supply (UPS) for residential customer.

Main objectives of the research are

Ø Modeling and simulation of Solar, Wind and grid tied hybrid system

Ø Analysis of optimum loading of hybrid supply system

Ø Economical analysis of optimization for hybrid system

7. Expected outcome of the research project

Following are the expected outcomes of research project:

Ø Un interrupted power supply when grid is not connected

Ø Optimum loading for hybrid supply system (Solar, Wind and Grid)

Ø Initial cost of solar and wind system is high but in hybrid connection it produces electricity at least cost

Ø It has many advantages that it produces no pollution and requires less maintenance.

8. Scope of the research Project

Now a days, world is facing the energy crisis the most optimist fact is that the main energy resources (Oil and natural Gas) are exhausted in 2050. In this scenario the only solution is finding and using new energy resources. Solar and wind energies are the solution in this scenario but the solar energy and wind energy highly depending on the climate conditions and also expensive but the combination of these technologies can be considered as hybrid supply system with high reliability to satisfy the electrical load of the residential customer.

Methodology Statement:

Methodology planning for this proposal topic is to optimum loading and economic analysis of hybrid supply system and Simulation as per the data collected from a house in defense Hyderabad where hybrid supply system is installed. However methodology for this proposal is divided into the following steps.

· Study of hybrid supply system:

First step of the project is to know how about hybrid supply system. Wind energy solar energy and grid connection.

· Survey of field

For the purpose of the data collection, we make a field survey of that house where hybrid supply system is installed Survey consists load of the customer and behavior of the load. Economic considerations and economical impacts over the customer

· Analysis

Collected data and simulation results will help to analyze the parameters of the hybrid supply system.
Analysis of cost and economic contribution of the hybrid supply system.

Comments

Popular posts from this blog

AUTO TRANSFORMER TAP CHANGING

Figure shows diagrammatically auto-transformer tap changing. Here, a mid-tapped auto-transformer or reactor is used. One of the lines is connected to its mid-tapping. One end, say a of this transformer is connected to a series of switches across the odd tappings and the other end b is connected to switches across even tappings. A short-circuiting switch S is connected across the auto-transformer and remains in the closed position under normal operation. In the normal operation, there is no inductive voltage drop across the auto-transformer. Referring to Figure, it is clear that with switch 5 closed, minimum secondary turns are in the circuit and hence the output voltage will be the lowest. On the other hand, the output voltage will be maximum when switch 1 is closed. Suppose now it is desired to alter the tapping point from position 5 to position 4 in order to raise the output voltage. For this purpose, short-circuiting switch S is opened, switch 4 is closed, then switch 5 is op...

COMPONENTS OF HIGH VOLTAGE DC TRANSMISSION SYSTEM

Figure: A schematic of a bipolar HVDC system identifying main components

PLUG REVERSING OF CAPACITOR START MOTORS

The capacitor start motors suffer from the disadvantage that they are not easily reversible due to the centrifugal switch connected in the auxiliary winding. The motor cannot be instantaneously reversed by simple control as the auxiliary winding remains disconnected till the motor comes near to zero speed. However, by proper design of the control circuit the motor can be made instantly reversible. This is accomplished by using an electromagnetic relay along with a special two contact centrifugal switch as shown in Figure. The circuit shown in Figure is for a small hoist using a capacitor start motor. The upper and lower limits of travel are controlled by two limit switches viz. LSU and LSD. When UP-push button is pressed, contactor U gets energized. Its contacts U 1  and U 2  energies the main winding. Closing of its contact U 3  causes relay R to get energized through the centrifugal switch contacts A—B. After the energization of relay R auxiliary winding gets ene...

BENEFITS OF UTILIZING FACTS DEVICES

The advantages of using FACTS devices in electrical transmission systems are described below. 1. MORE UTILIZATION OF EXISTING TRANSMISSION SYSTEM In all the countries, the power demand is increasing day by day to transfer the electrical power and controlling the load flow of the transmission system is very necessary this can be achieved by more load centers which can change frequently. Addition of new transmission line is very costly to take the increased load on the system; in that case FACTS devices are much economical to meet the increased load on the same transmission lines. 2. MORE INCREASED TRANSIENT AND DYNAMIC STABILITY OF THE SYSTEM The Long transmission lines are inter-connected with grids to absorb the changing the loading of the transmission line and it is also seen that there should be no line fault creates in the line / transmission system. By doing this the power flow is reduced and transmission line can be trip. By the use of FACTS devices high power t...

PRIMARY SECONDARY AND TERTIARY FREQUENCY CONTROL IN POWER SYSTEMS

Primary, Secondary and Tertiary Frequency Control in Power Systems Author: Engr. Aneel Kumar Keywords: frequency control, primary frequency control, automatic generation control (AGC), tertiary control, load-frequency control, grid stability. Frequency control keeps the power grid stable by balancing generation and load. When generation and demand drift apart, system frequency moves away from its nominal value (50 or 60 Hz). Grids rely on three hierarchical control layers — Primary , Secondary (AGC), and Tertiary — to arrest frequency deviation, restore the set-point and optimize generation dispatch. Related: Power System Stability — causes & mitigation Overview of primary, secondary and tertiary frequency control in power systems. ⚡ Primary Frequency Control (Droop Control) Primary control is a fast, local response implemented by generator governors (dro...

AC Transmission Line and Reactive Power Compensation: A Detailed Overview

  Introduction The efficient operation of modern power systems depends significantly on the management of AC transmission lines and reactive power. Reactive power compensation is a vital technique for maintaining voltage stability, improving power transfer capability, and reducing system losses. This article explores the principles of AC transmission lines, the need for reactive power compensation, and its benefits in power systems. Keywords: Reactive Power Compensation Benefits, STATCOM vs SVC Efficiency, Power Transmission Stability Solutions, Voltage Stability in Long-Distance Grids, Dynamic Reactive Power Compensation.      Fundamentals of AC Transmission Lines AC transmission lines are the backbone of modern power systems, connecting generation stations to distribution networks. They have distributed electrical parameters such as resistance ( R R R ), inductance ( L L ), capacitance ( C C ), and conductance ( G G ) along their length. These parameters influence ...

Breaker Schemes in Substations

Breaker Schemes in Substations — Types, Design, Advantages, Disadvantages, and Comparison Author: Engr. Aneel Kumar Figure 1: Infographic overview of breaker schemes commonly used in substations. Introduction The breaker scheme or busbar arrangement in a substation defines how incoming feeders, outgoing feeders, and power transformers are connected to the bus. The choice of scheme has a direct impact on system reliability, maintainability, safety, and cost . A simple bus scheme is economical but vulnerable to outages, while advanced schemes such as breaker-and-a-half or double-bus/double-breaker provide very high reliability but at much higher cost and design complexity. Engineers select breaker schemes considering fault tolerance, maintenance needs, space requirements, expansion possibilities, protection coordination, and capital investment . Below, we explain eac...